Techno-Economic Analysis of Solar Photo-Voltaic/Diesel Generator Hybrid System Using Different Energy Storage Technologies for Isolated Islands of India

Publication Year: 2021

Author(s): Kumar P, Pal N, Sharma H

Abstract:

This study solely examines the techno-economic performance of a solar photovoltaic (SPV) and diesel generator (DG) hybrid system utilizing four distinct battery energy storage (BES) technologies: lead-acid battery, lithium-ion battery, vanadium redox battery, and zinc-bromine flow (ZBF) battery, specifically for the isolated Andaman and Nicobar and Lakshadweep islands of India. The analysis utilized the Hybrid Optimization Model for Electric Renewables (HOMER) software at Baratang and Minicoy islands of Andaman & Nicobar and Lakshadweep, respectively, revealing that the SPV/DG/ZBF hybrid system (20 kW SPV, 7 kW DG, 100 kWh ZBF batteries, and 20 kW converter) is the most techno-economically viable optimized solution for both locations. The net present cost, levelized cost of energy, and operating cost for this configuration are $23,927.21, $0.167/kWh, and $338.20, respectively, for Baratang Island; and $22,366.64, $0.155/kWh, and $217.49, respectively, for Minicoy Island. The baseline configuration of this system was utilized to extend the analysis to various BES technologies, assessing performance characteristics such as system cost, return on investment, simple payback period, energy output, pollutant emissions, and renewable penetration.

Document Details

Source of Publication: Journal of Energy Storage

Issues / Volume : 41, 102965

Doi Number: https://doi.org/10.1016/j.est.2021.102965

Document Type: Journal Article

Reviewed: Peer Reviewed

Country: India

Publisher/Organisation: Elsevier, Ltd.

Theme: Applications and Use-cases

Subtheme: Grid-Scale Applications, Off-grid and Microgrid Systems, Renewable Energy Integration

Tags: Levelized Cost of Storage (LCOS), Others